Rocket UPS & VRLA Batteries

Premium industrial VRLA standby batteries delivering stable discharge characteristics for critical loads. Northern EPES supplies and installs genuine battery banks from India's leading manufacturers: EXIDE, Amaron Quanta, HBL, and Rocket with comprehensive sizing calculations and factory warranties.

100% Genuine OEM
Factory Fresh Batch Warranty
Technical Sizing
VRLA, AGM & Tubular Cells
Turnkey Installation
Racks, Cabling & Breakers

Request Battery Bank Quotation

Share your UPS make, DC voltage, and runtime for immediate technical proposal.

Brand Deep Dive

Rocket UPS & VRLA Batteries Overview & Engineering Profile

Rocket VRLA batteries are recognized globally for their precision manufacturing and reliable standby power characteristics. Northern EPES provides genuine Rocket batteries for online UPS, offline UPS, IT equipment, telecommunication systems, emergency lighting, and industrial DC control circuits.

Verified Rocket UPS & VRLA Batteries Applications

⚑ Online & Offline UPS systems
⚑ IT server enclosures & data storage rooms
⚑ Telecom exchange towers & PBX systems
⚑ Electronic access control, fire alarms & security systems
⚑ Emergency evacuation lighting & signage
⚑ Industrial DC backup systems
Engineering Methodology

Technical UPS Battery Sizing & Determination

Choosing the correct battery make, Ah capacity, and configuration is essential for achieving the required runtime without compromising UPS lifespan or safety. Northern EPES engineers calculate your battery bank according to 5 key engineering steps:

1

UPS Active Capacity

We calculate the exact DC power requirement in Watts based on the UPS kVA, load power factor (e.g. 0.8, 0.9, or 1.0), and inverter DC-to-AC conversion efficiency.

2

Target Backup Runtime

Battery Ah rating is selected according to the required runtime: 15 Mins, 30 Mins, 45 Mins, 60 Mins, 90 Mins, 2 Hours, or 4+ Hours deep autonomy.

3

DC Bus Voltage & String Length

The required number of 12V or 2V battery blocks in series is determined based on the inverter DC bus voltage (e.g. 36V, 72V, 96V, 192V, 240V, 384V, or 480V DC).

4

Battery Ah Rating & Discharge Curves

We cross-reference the manufacturer's constant power discharge tables (Watts per Cell) down to the designated end-of-discharge cut-off voltage (1.67V to 1.75V/cell).

5

Complete Mechanical & Electrical Configuration

Every battery bank proposal includes: Batteries + Tiered Powder-Coated Racks + Interlinks + Copper Cables + Crimped Lugs + DC Isolation Breaker/Fuse Box + Turnkey Installation.

Battery Solutions We Offer (Technology Comparison)

Battery Technology Typical Application & Duty Profile Design Service Life
SMF VRLA (12V) Commercial UPS, corporate IT data centers & workstation power backup 3 – 5 Years
AGM VRLA (12V High-Rate) High-rate short-duration data center UPS (10–15 min discharge) 5 – 8 Years
Tubular Lead-Acid Industrial power plants, frequent long power outages & inverter setups 5 – 7 Years
Industrial 2V Stationary Cell Large megawatt UPS, electrical substations, power generation & nuclear plants 12 – 15+ Years
High-Rate UPS Battery Hyperscale cloud data centers & financial trading mission-critical loads 8 – 10 Years
Telecom Battery Telecommunication towers, 4G/5G BTS sites & remote repeater shelters 5 – 10 Years
Solar Deep-Cycle Battery Off-grid and hybrid solar installations with deep daily cyclical discharge 5 – 7 Years

Complete UPS Battery Installation & Commissioning

Northern EPES provides end-to-end battery solutions, not just battery supply. Every deployment is managed by licensed electrical supervisors adhering to CEA Safety Regulations:

βœ” Technical battery selection & sizing calculations
βœ” Backup runtime optimization & temperature derating
βœ” Custom multi-tier powder-coated battery rack supply
βœ” Flexible copper interconnects & heavy-duty DC cable supply
βœ” DC circuit breaker & semiconductor fuse protection boxes
βœ” On-site mechanical placement, interlinking, and torque verification
βœ” UPS commissioning & float/boost charging parameter calibration
βœ” Preventive battery maintenance, impedance testing & thermal imaging
βœ” Environmentally compliant old battery buyback & scrap disposal