⚑ Industrial Battery Systems β˜… Authorized Multi-Brand Supplier

Amaron Quanta UPS Batteries

India's highest-selling fail-safe SMF VRLA batteries powered by patented Radgrid technology. Northern EPES supplies and installs genuine battery banks from India's leading manufacturers: EXIDE, Amaron Quanta, HBL, and Rocket with comprehensive sizing calculations and factory warranties.

100% Genuine OEM
Factory Fresh Batch Warranty
Technical Sizing
VRLA, AGM & Tubular Cells
Turnkey Installation
Racks, Cabling & Breakers

Request Battery Bank Quotation

Share your UPS make, DC voltage, and runtime for immediate technical proposal.

Brand Deep Dive

Amaron Quanta UPS Batteries Overview & Engineering Profile

Amaron Quanta batteries are the preferred choice for commercial, IT, and industrial UPS installations requiring compact, maintenance-free, and high-rate discharge battery power. Featuring patented Radgrid plate architecture and heavy-duty poly-insulator containers, Quanta delivers rapid recharge and exceptional cycle life.

Why Choose Amaron Quanta UPS Batteries?

βœ” Factory-sealed maintenance-free design eliminates water topping-up and acid spill risk
βœ” Patented Radgrid technology delivers low internal resistance and high-rate discharge currents
βœ” Heavy-duty polypropylene container withstands thermal expansion and mechanical vibration
βœ” Patented lead alloy composition minimizes self-discharge and extends shelf life up to 6 months
βœ” Flame-arrestor vent plugs provide safety against external sparks and flash-back

Verified Amaron Quanta UPS Batteries Applications

⚑ Enterprise IT data centers, server racks & network closets
⚑ Commercial corporate headquarters, BFSI branches & ATMs
⚑ Hospital diagnostic MRI, CT, and ICU power backup
⚑ Industrial automation control panels & PLC backup
⚑ Telecom BTS sites & security command consoles

Standard Factory Ratings & Typical Application Sizing

Battery Model & Rating Typical UPS Capacity & Application
Quanta 12V 26Ah Workstations & 1–3kVA UPS systems
Quanta 12V 42Ah Small server rooms & 3–6kVA UPS
Quanta 12V 65Ah Enterprise servers & 10–20kVA UPS
Quanta 12V 84Ah Long backup systems & 20–40kVA UPS
Quanta 12V 100Ah High-density data centers & 30–80kVA UPS
Quanta 12V 120Ah Medium-to-large UPS & industrial backup
Quanta 12V 150Ah Industrial manufacturing & 100kVA+ UPS
Quanta 12V 200Ah Megawatt data centers & long-duration autonomy
Engineering Methodology

Technical UPS Battery Sizing & Determination

Choosing the correct battery make, Ah capacity, and configuration is essential for achieving the required runtime without compromising UPS lifespan or safety. Northern EPES engineers calculate your battery bank according to 5 key engineering steps:

1

UPS Active Capacity

We calculate the exact DC power requirement in Watts based on the UPS kVA, load power factor (e.g. 0.8, 0.9, or 1.0), and inverter DC-to-AC conversion efficiency.

2

Target Backup Runtime

Battery Ah rating is selected according to the required runtime: 15 Mins, 30 Mins, 45 Mins, 60 Mins, 90 Mins, 2 Hours, or 4+ Hours deep autonomy.

3

DC Bus Voltage & String Length

The required number of 12V or 2V battery blocks in series is determined based on the inverter DC bus voltage (e.g. 36V, 72V, 96V, 192V, 240V, 384V, or 480V DC).

4

Battery Ah Rating & Discharge Curves

We cross-reference the manufacturer's constant power discharge tables (Watts per Cell) down to the designated end-of-discharge cut-off voltage (1.67V to 1.75V/cell).

5

Complete Mechanical & Electrical Configuration

Every battery bank proposal includes: Batteries + Tiered Powder-Coated Racks + Interlinks + Copper Cables + Crimped Lugs + DC Isolation Breaker/Fuse Box + Turnkey Installation.

Battery Solutions We Offer (Technology Comparison)

Battery Technology Typical Application & Duty Profile Design Service Life
SMF VRLA (12V) Commercial UPS, corporate IT data centers & workstation power backup 3 – 5 Years
AGM VRLA (12V High-Rate) High-rate short-duration data center UPS (10–15 min discharge) 5 – 8 Years
Tubular Lead-Acid Industrial power plants, frequent long power outages & inverter setups 5 – 7 Years
Industrial 2V Stationary Cell Large megawatt UPS, electrical substations, power generation & nuclear plants 12 – 15+ Years
High-Rate UPS Battery Hyperscale cloud data centers & financial trading mission-critical loads 8 – 10 Years
Telecom Battery Telecommunication towers, 4G/5G BTS sites & remote repeater shelters 5 – 10 Years
Solar Deep-Cycle Battery Off-grid and hybrid solar installations with deep daily cyclical discharge 5 – 7 Years

Complete UPS Battery Installation & Commissioning

Northern EPES provides end-to-end battery solutions, not just battery supply. Every deployment is managed by licensed electrical supervisors adhering to CEA Safety Regulations:

βœ” Technical battery selection & sizing calculations
βœ” Backup runtime optimization & temperature derating
βœ” Custom multi-tier powder-coated battery rack supply
βœ” Flexible copper interconnects & heavy-duty DC cable supply
βœ” DC circuit breaker & semiconductor fuse protection boxes
βœ” On-site mechanical placement, interlinking, and torque verification
βœ” UPS commissioning & float/boost charging parameter calibration
βœ” Preventive battery maintenance, impedance testing & thermal imaging
βœ” Environmentally compliant old battery buyback & scrap disposal

Get the Right Battery Bank for Your UPS

Share your UPS capacity, existing battery details, and required backup duration. Our certified battery sizing engineers will recommend the exact make, Ah rating, quantity, and rack layout.

Request Battery Proposal ⚑ Call Battery Specialist: +91 81042 95600