EXIDE Industrial & UPS Batteries Overview & Engineering Profile
EXIDE offers a comprehensive range of batteries for industrial UPS and standby power applications. Its industrial portfolio includes SMF VRLA, medium VRLA, tubular and other standby battery technologies. Northern EPES supplies genuine EXIDE batteries for UPS systems, data centres, industrial backup power, telecom systems, emergency power, solar applications, and electrical infrastructure across India.
Key Battery Categories
EXIDE SMF / VRLA Batteries (Powersafe)
Maintenance-free sealed lead-acid batteries suitable for UPS and critical backup applications. EXIDE's Powersafe range uses sealed construction and immobilised electrolyte, eliminating routine electrolyte topping-up and acid fumes.
EXIDE NXT PLUS
Next-generation medium VRLA batteries designed for demanding industrial UPS, deep cyclical discharges, and high-temperature Indian operating conditions.
EXIDE EL / EL PLUS Tubular Batteries
Industrial tubular plate batteries available in multiple Ah capacities. Renowned for rugged cyclical durability, long service life, and high recovery from deep discharges.
EXIDE Industrial Tubular Batteries
Heavy-duty stationary batteries engineered for demanding utility substations, power plant switchgear, and large multi-kVA industrial UPS installations.
Verified EXIDE Industrial & UPS Batteries Applications
Technical UPS Battery Sizing & Determination
Choosing the correct battery make, Ah capacity, and configuration is essential for achieving the required runtime without compromising UPS lifespan or safety. Northern EPES engineers calculate your battery bank according to 5 key engineering steps:
UPS Active Capacity
We calculate the exact DC power requirement in Watts based on the UPS kVA, load power factor (e.g. 0.8, 0.9, or 1.0), and inverter DC-to-AC conversion efficiency.
Target Backup Runtime
Battery Ah rating is selected according to the required runtime: 15 Mins, 30 Mins, 45 Mins, 60 Mins, 90 Mins, 2 Hours, or 4+ Hours deep autonomy.
DC Bus Voltage & String Length
The required number of 12V or 2V battery blocks in series is determined based on the inverter DC bus voltage (e.g. 36V, 72V, 96V, 192V, 240V, 384V, or 480V DC).
Battery Ah Rating & Discharge Curves
We cross-reference the manufacturer's constant power discharge tables (Watts per Cell) down to the designated end-of-discharge cut-off voltage (1.67V to 1.75V/cell).
Complete Mechanical & Electrical Configuration
Every battery bank proposal includes: Batteries + Tiered Powder-Coated Racks + Interlinks + Copper Cables + Crimped Lugs + DC Isolation Breaker/Fuse Box + Turnkey Installation.
Battery Solutions We Offer (Technology Comparison)
Complete UPS Battery Installation & Commissioning
Northern EPES provides end-to-end battery solutions, not just battery supply. Every deployment is managed by licensed electrical supervisors adhering to CEA Safety Regulations:
Get the Right Battery Bank for Your UPS
Share your UPS capacity, existing battery details, and required backup duration. Our certified battery sizing engineers will recommend the exact make, Ah rating, quantity, and rack layout.